MFTR Water Retun Valve Fix

MFTRv2: Water Valve(Return) maintenance procedure

Problem: If you find the "Water Valve(Return)" to be not working, please use the below procedure to hopefully resolve the issue.

Potential Resolution:
1. Go to the MFTR configuration page as shown in the image below:


2. Under "VALVE STATUS", please click on "Close" against the "Water Valve(Return)"
3. Set the "Pressure Set Point" to be 3.0 bars
4. Click on the "START" button against "PUMP" (To start the pump)
5. Let the pump run until the "Inlet Pressure / Outlet Pressure" reach nearly 3.0 bars of pressure. When the pressure reaches close to 3.0, then please click on "STOP" against the PUMP (To stop the pump)
6. Let the system be as is for 10 minutes (approximately).
7. After a wait time of approx. 10 minutes, please click on the "Open" button against the "Water Valve(Return)" to open the Water Valve(Return).
8. The pressure should now be released.

The above procedure should hopefully work the valves back to working condition , which might flush off any potential dirt  stuck on the MFTR after a prolonged period of use.

If the above procedure does not help to get the Water Valve(Return) back to the normal working condition, then please contact the Mouldflo Support team for further assistance in troubleshooting the issue.